CV9 Master Catalog

Specifications subject to change without notice or incurring obligation Directional Control Valves 11 11.29 3-12-08 1.50 .63 1.03 1.25 1/2 NPT 10-32 Exhaust Port Housing can rotate 360 ° 1.03 10-32 Exhaust Port 1.50 .75 .63 Housing can rotate 360 ° 1.58 .44 .88 10-32 Exhaust Port .43 .22 (11 mm) spacing .47 .37 .57 1.50 Line Terminals .25 x .03 Ground Terminal .25 x .03 Housing can rotate 360 ° 53 STYLE Stocked Coils and Housings Conduit Housing “C” and Grommet Housing “G” Non-molded – Class A 221°F (105°C) Rating, 24" Leads of AWG #18 Wire. Stocked Voltages: 24, 120 and 240 Volt at 50 or 60 Hertz; 6, 12 and 24 Volt DC; Others available, see Options on page 11.30. Temperature Range: 0°F (–18°C) to + 104°F (+40°C), ambient. 0°F (–18°C) to + 150°F (+65°C), media. Typical Response Times: AC 4 to 8 milliseconds to open or close; DC 9 to 15 milliseconds to open; DC 5 to 12 milliseconds to close. To compute current requirements (±15%) divide factor shown below by voltage Male Mini-DIN Housing “F” Molded – Water Tight - Class A 221°F (105°C) IP65 Coil Rating. European (DIN) Style – 11 mm spacing. See page 11.30 for connectors or contact your local distributor for additional choices. Can also be connected with individual .25" quick connect terminals. Stocked Voltages: 24, 120 and 240 Volt at 50 or 60 Hertz; 12 and 24 Volt DC; Others available, see Options on page 11.30. Temperature Range: 0°F (–18°C) to + 104°F (+40°C), ambient. 0°F (–18°C) to + 150°F (+65°C), media. Typical Response Times: AC 4 to 8 milliseconds to open or close; DC 9 to 15 milliseconds to open; DC 5 to 12 milliseconds to close. To compute current requirements (±15%) divide factor shown below by voltage. AC Volts, 60 Hertz DC Volts Inrush, Amp Function Inrush, Amp Holding, Amp or Holding, Amp 2 Way NC 14.4 ÷ Volts 9.7 ÷ Volts 10.4 ÷ Volts 2 Way NO 3 Way NC or NO Examples 15.2 ÷ 120 = 11.8 ÷ 120 = 10.4 ÷ 12 = .13 Amp .10 Amp .87 Amp 15.2 ÷ Volts 11.8 ÷ Volts 10.4 ÷ Volts AC Volts, 60 Hertz DC Volts Inrush, Amp Function Inrush, Amp Holding, Amp or Holding, Amp 2 Way NC 13.2 ÷ Volts 7.8 ÷ Volts 2 Way NO 3 Way NC or NO Examples 15.2 ÷ 120 = 9.0 ÷ 120 = 7.2 ÷ 12 = .13 Amp .08 Amp .60 Amp 15.2 ÷ Volts 9.0 ÷ Volts 7.2 ÷ Volts Conduit Housing “C” Grommet Housing “G” Male Mini-DIN Housing “F” Spade terminals accept miniature rectangular quick connect socket (Female DIN style connector, 11 mm spac- ing) or individual .25" quick connect terminals. Sol noid, Coil and Housing Information 53 Style

RkJQdWJsaXNoZXIy NDI5NDE=