FML and FHL Swing Clamps

Page 6 FHL Series FHL FHLD FHL FHLDT FHLT See prices on page 7 11-18-09 ø63 not available ø63 not available * * During the retract stroke Bore size (mm ) ø25, ø32, ø40, ø50, ø63 Operating media 3HWUROHXP EDVHG K\GUDXOLF ÁXLG Min. operating pressure 2Mpa(20kgf/cm2)285psi Max. operating pressure 7Mpa(70kgf/cm2) 1000psi Temperature range 0°C(32°F) ~ + 80°C(176°F) Swing angle 90° ± 2° Rotation direction L= counter-clockwise; R = clockwise Lubrication None required Stroke action See page 8 FHL FHLD FHLT FHLDT 1000 psi max. Bore Size (mm) Piston rod Effective area (in 2 ) Ø25 Ø32 Ø40 Ø50 Ø63 ø18 ø20 ø20 ø20 ø25 Theoretical retract force (lbf) 285 psi 105 216 414 727 1159 355 psi 132 270 518 909 1449 427 psi 158 324 621 1091 1739 498 psi 185 378 725 1273 2029 569 psi 211 432 828 1455 2319 640 psi 236 485 932 1636 2609 710 psi 263 539 1036 1817 2889 782 psi 289 594 1141 2001 3182 924 psi 342 702 1349 2365 3760 1000 psi 370 760 1460 2560 4070 0.37 0.76 1.46 2.56 4.07 853 psi 315 648 1245 2183 3471 3OHDVH YLVLW KWWS SRUWDO IDEFR DLU FRP FRQðJXUH SKS IRU FXUUHQW SULFLQJ 6SHFLðFDWLRQV DQG SULFHV VXEMHFW WR FKDQJH ZLWKRXW QRWLFH RU LQFXUULQJ REOLJDWLRQ