43 SPECIALS/Engineering Data Specifications and prices are subject to change without notice or incurring obligations. Tel: 352-373-3578; Fax 352-375-8024 • email: service@fabco-air.com LDT ELECTRICAL INFORMATION INPUT VOLTAGE 7 VDC to 30 VDC CURRENT DRAW 40mA at 24 VDC OUTPUT ANALOG Absolute analog position via digital-to-analog converter 0 to 10 VDC 10 to 0 VDC -10 to 10 VDC 10 to -10 VDC 0 to 5 VDC 5 to 0 VDC -5 to 5 VDC 5 to -5 VDC 4 to 20mA 20 to 4mA DIGITAL Digital available upon request RESOLUTION INTERNAL 0.00006 ANALOG OUTPUT 16-Bit NON-LINEARITY/ ACCURACY <0.01% or +/- 0.005", whichever is greater (+/- 0.002 typical) REPEATABILITY 953D REPEATABILITY Equal to resolution of controller 953A REPEATABILITY Equal to resolution 953SSI REPEATABILITY Equal to output resolution HYSTERESIS .001” (.025 mm) maximum OPERATING TEMPERATURE HEAD ELECTRONICS -40° to 185°F (-40° to 70° C) GUIDE TUBE -40° to 221°F (-40° to 105° C) OPERATING PRESSURE 3000 psi operational, 8,000 psi spike SPAN LENGTH 1” - 300” NULL ZONE 2" DEAD ZONE 2.50" CONNECTORS 5 pin 12mm Euro micro Potted pigtail assembly available optionally UPDATE TIME 2 MS typically 12-7-16